China Occupational Medicine ; (6): 85-88, 2021.
Article in Chinese | WPRIM | ID: wpr-881976

ABSTRACT

OBJECTIVE: To explore a method for detecting volatile organic compounds(VOCs) in air by a portable gas chromatography-mass spectrometer(GC-MS). METHODS: A portable GC-MS hand-held probe was used for sampling and detection. All effluent components were qualitatively analyzed by the standard spectral library of the United State National Institute of Standards and Technology. The percentage of peak area of the component was calculated by normalization method. The static distribution method was adopted in the semi-quantitative and quantitative analysis using nitrogen as the diluting gas to prepare different mass concentration of 13 kinds of VOCs in the mixed standard gas. The retention time and characteristic ions were used for qualitative analysis, and the quantitated full scanning mode was used for quantitative analysis.RESULTS: The minimum detected mass concentration of the 13 chemical harmful factors was 0.02-0.10 mg/m~3, and the minimum quantitative mass concentration was 0.07-0.38 mg/m~3. The recovery rate was 84.76%-116.56%, and the within-and between-run relative standard deviations were 4.10%-12.50% and 8.17%-14.36%, respectively. CONCLUSION: The portable GC-MS instrument could be used for qualitative alalysis, peak area percentage determination, semi-quantitative and quantitative analysis of VOCs in the workplace air or sudden chemical poisoning accidents.

2.
China Occupational Medicine ; (6): 425-430, 2021.
Article in Chinese | WPRIM | ID: wpr-923212

ABSTRACT

OBJECTIVE: To prepare and develop a GDH-2 air sampling tube for detecting 12 kinds of chlorobenzenes(CBs) in workplace air and to establish a matching detecting method. METHODS: The self-developed GDH-2 air sampling tube was filled with ion exchange resin and activated carbon, and the mass ratio was 10 ∶1. The GDH-2 air sampling tube was used to collect 12 kinds of CBs with coexistence of gaseous and aerosol in the air. After elution with toluene, they were separated on a chromatographic column and determined by microcell electron capture detector. RESULTS: The quantitative detecting range of the method was 0.51×10~(-3)-6 000.00 mg/L, with the correlation coefficients greater than 0.999 4. The minimum detection concentration was 0.02-61.99 μg/m~3, and the minimum quantitative concentration was 0.05-206.62 μg/m~3. The average desorption efficiency was 90.8%-104.0%. The within-run relative standard deviation(RSD) was 1.0%-5.7%, and the between-run RSD was 3.0%-7.3%. The samples can be stored at room temperature for at least 26 days. CONCLUSION: The self-developed GDH-2 air sampling tube and its matching measuring method can be used for the collection and determination of the 12 kinds of CBs in the air of workplace.

3.
China Occupational Medicine ; (6): 543-547, 2021.
Article in Chinese | WPRIM | ID: wpr-923085

ABSTRACT

OBJECTIVE: To establish a method for simultaneous determination of 12 kinds of chlorobenzene compound(CBs) in workplace air using portable gas chromatography-mass spectrometry(GC-MS) technique. METHODS: The GDH-3 air sampling tube was developed independently, and were used to collect the 12 kinds of CBs in the vapor state and aerosol state in the air. After elution with toluene solvent, portable GC-MS method was used for detection. Fast chromatographic column was used for separation, and then qualitatively analyzed with retention time and characteristics of the ions, and quantitative analyzed by standard curves. RESULTS: The quantitative determination ranges of the 12 kinds of CBs were 0.20-200.00 mg/L. All the correlative coefficients were greater than 0.998 3. All the minimum quantitative concentration was 0.01 mg/m~3, and all the minimum quantitative mass concentration was 0.04 mg/m~(3 )(15 L sample). The average elution efficiency was 88.97%-116.86%. The within-run and the between-run relative standard deviation was 10.15%-13.48% and 12.87%-19.66%, respectively. All the sampling efficiencies were>90.00%. CONCLUSION: The portable GC-MS technique could be used for rapid qualitative and quantitative detection of 12 kinds of CBs in workplace air.

4.
China Occupational Medicine ; (6): 197-200, 2016.
Article in Chinese | WPRIM | ID: wpr-876932

ABSTRACT

OBJECTIVE: To establish a method for testing tetrahydrofuran( THF) in workplace air by solvent desorption gas chromatography. METHODS: The air samples were collected by activated carbon tube,desorbed with carbon disulfide solution,then separated by capillary column and detected by flame ionization detector. RESULTS: The linearity range of THF concentration was 1. 78-8 892. 00 mg / L,and the correlation coefficient was 0. 999 9. The minimum detection limit of THF was 0. 09 mg / m3. The minimum quantitative concentration was 0. 27 mg / m3( 3. 00 L air collection). The average desorption efficiency of THF was 94. 29%-96. 46% when placed overnight at the room temperature. The within-run and the between-run relative standard deviation were 0. 30%-0. 91% and 0. 66%-1. 23% respectively. THF sample could be stored at room temperature for at least 8 days. CONCLUSION: The method could be widely applied in sampling and detection of THF in workplace air.